What was found
SHEAR FITTING AT STATION 540 AND RBL 6.14 IS CRACKED. SUPPORT TASK NSA EMX N/R 00100. HANGAR N/R 7000548. REMOVED AND REPLACED SHEAR FITTING AT STATION 540 AND RBL 6.14 IAW BAC DWG 111A2000 REV ORIGINAL AND B737-800 SRM 51-40-02 SEE NSA EMX N/R 00100 AND HANGER N/R 7000548 FOR WORK ACCOMPLISHED CIR C/W DATA WAS TRANSCRIBED FROM NSA EMX N/R 00100 AND WORK VERIFIED ALL RII REQUIREMENTS C/W. N/R COMPLETE SSFR REPORT, FORM 46-0024,