What was found
AFT CARGO COMPT - BELOW FLOOR SHEAR TIE FOUND CORROSION AT STA 1417 BTN S37L - S38L TRANSFER REF. NON-ROUTINE HX NRC WO.1731314 AND ORIGINATED BY EMP NO. V896820 BULK CARGO COMPT - BELOW FLOOR STA 1417 BTN S37L - S38L SHEAR TIE REPLACED AS PER SRM 51-10-02 AND NEW SHEAR TIE INSTALLED AS PER SRM 51-40-02. ATT. FORM 44-0008 ITEM 1 TO 17 ACCOMPLISHED WORK ACCOMPLISHED BY MECHANIC V926499 INSPECTED BY V925649 RII INSPECT IS OKAY. APPROVED BY HX 129272