What was found
SKIN AT EXTERNAL A/C CONNECTION CORRODED AND PULLING THROUGH FASTENERS. SEE ATTACHED IMAGES FUSELAGE SKIN REPAIR IN ACCORDANCE WITH PART 2 OF EC/RA 5330-07087 ON OR BEFORE 20 MAY 2025 PERFORMED INTERIM REPAIR PER EC/RA 5330-07087 AT STA 500H-540 LOWER SKIN. PLACE ON DIP TO PERFORM AN INSPECTION OF THE INITIATED A DTA DIP FOR THE BS 500H ? 540 & STR 26L - 26R TOMC-APPROVAL FROM SC1ELBYC COMMENT FUSELAGE SKIN REPAIR TO PERFORM AN INSPECTION OF THE FUSELAGE SKIN REPAIR IN ACCORDANCE WITH PART 2. A. OF ECRA 5330-07087 ON OR BEFORE 20 MAY 2025. CHECKED OK REVIEWED RECORDS UPDATE.