What was found
REFERENCE L/P 4677633. FOR INTERIM SKIN REPAIR AT STATION 500H-540 STR 26L-26R. REQUIRES 2ND DTA DIP NOTE TO PLANNING: THIS EC/RA IS BEING EVALUATED FOR DAMAGE SUPPLEMENTAL INSPECTIONS. THE INSPECTION CRITERIA WILL BE TOLERANCE. UNDER 14CFR 26.43(D) WHICH WILL REQUIRE REPEAT / INCLUDED IN PART 2 AT THE CONCLUSION ON THE EVALUATION. PLACED ON DIP FOR PLANNING TO CONTACT ENGINEERING AFTER 20 MARCH 2025 BUT BEFORE 20 APRIL 2025 FOR THE INSPECTION REQUIREMENTS. CHECKED OK PLACED ON DIP FOR PLANNING TO CONTACT ENGINEERING AFTER 20 MARCH SUPPLEMENTAL INSPECTIONS.