What was found
DUE TO FLAP ASYMETRY, TECH SUPPORT REQUEST THAT RESOLVERS 4 AND 5 BE CHANGED. REF L/P 4742026 FOR CONTINUATION OF TROUBLESHOOTING. CHECKED THE REMOVED & REPLACED FLAP POS. XMTR #4 REF AMM 27-51-45, NEEDS REMOVED & REPLACED FLAP POS. XMTR #5 REF AMM 27-51-45, NEEDS INSTALLED #4 FLAP POS XMTR PARTS USED: 1604003,QTY :1 INSTALLED #5 FLAP POS XMTR PARTS USED 1154059,QTY :1 CURRENT ADJUSTMENT READINGS AT THE 20* AND 5* POSITIONS OF THE ADJUSTMENT & OPS CHECKS. PN OFF 18-1958-20, SN OFF 0528, PN ON ADJUSTMENT & OPS CHECKS. PN OFF 18-1958-20, SN OFF 0542 PN ON ROTABLE PARTS CHANGE WAS INDICATED - TT # 1604003 SN OFF 0528 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1154059 SN OFF 0542 FLAP POSITION TRANSMITTERS #4(M476) AND #5(M492) IAW 767-3 AMM 18-1958-20, SN 1615PARTS USED: 76-2754-9-0002,QTY :1 18-1958-20, SN 0732. 27-51-45-822-161. SEE ATTACHED PICS FOR VALUES. ADD EMP:234643 IPC REFERENCE # 27-51-45-05 IPC REFERENCE # 27-51-45-05 ADJUSTED #4 & #5 FLAP POS XMTRS REF AMM 27-51-45, OPS CHECK GOOD. TRANSMITTER, FL OFF 76-2754-9-0002 0528 ON 76-2754-9-0002 1615 TRANSMITTER, FL OFF 76-2754-9-0002 0542 ON 76-2754-9-0002 0732