What was found
Y SYS LO PR MANIFOLD. FOUND YELLOW SYS PTU MANIFOLD PTU SUPPLY CHECK VALVE NUT/SEAL PARTS ADDED FOUND EXTRUDED O-RING ON MANIFOLD CHECK VALVE. DISCONNECTED PTU REUPLOAD PICTURE LEAKING OR MANIFOLD CRACKED AT THE MATING SURFACE, SEE IMAGE QUICK-DISCONNECT LINE AND REMOVED CHECK VALVE. INSTALLED NEW O-RING ON CHECK VALVE REF IPC 29-13-15 & CMM 29-13-15. RECONNECTED QUICK-DISCONNECT LINE. NEED LEAK CHECK OF PTU ADD EMP:U403011,U403008,U092939 LEAK CHECKED PTU MANIFOLD REF. AMM 20-23-00, NO LEAKS NOTED. OPS CHECK GOOD. ADD EMP:U404925