What was found
ON TO UNSCHD STAB TRIM EICAS REJECTED TO AT APPROX 30KNTS REPLACED RIGHT LSTM IAW AMM 27-48-01-024-001 AND STAB POSITION MODULE BOARD M10410. PRFORMED OPS CHECK AMM27-41-00-501 & 27-48-00-501 & 27-48-03-424-009 ALL TEST PASSED. PARTS USED: 1435135,QTY :1 19-2748-9-9001,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1435135 SN OFF 6774 TT # 1413950 SN OFF 2534 IPC REFERENCE # SEE IPC CIRCUIT, PRINTE OFF 19-2748-9-9001 2534 ON 19-2748-9-9001 2828 TRANSMITTER, PO OFF 19-2748-9-0003 6774 ON 19-2748-9-0003 5603.