What was found
FOUND 1 EA LIGHTNING STRIKE ON SKIN AT LHS FR8 Z-339 CREATED BY MEHRDAD PARSA 91105046 60000 FC/120000 FH IAW SRI 53-11-11-205-037 REPAIR EMBODIMENT AT ZONE 1. PERFORMED PERMANENT REPAIR CATEGORY B IAW SRM 53-11-11-3000-041. IT IS NECESSARY TO INSPECT THIS REPAIR AT DEFINED INTERVALS OF ADD EMP:V934700 MAE 206QC OK TO CARRY PER SRI 53-11-11-205-037, REQUIRES INSPECTION AT TOMC-APPROVAL FROM SC1ELBYC COMMENT 60000 F/C''S OR 120000F/H''S FROM REPAIR EMBODIMENT. QC QC REVIEWED INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE.