What was found
FLOOR BEAM Y765 UPPER SURFACE HAS SEVERAL SPOTS WITH CORROSION FR66 TO FR68 DOT 41-20 REMOVED CORROSION IAW SRM 51-74-00 D: 0.045 OUT OF LIMITS IAW SR 51-75-12 SEE ATTACHMENT 44-0008 EMP#: V936322 WORK ACCOMPLISHED M 53-41-14-283-009, RECEIVE NEW PART, P/N D5347219320000, LOCATE AT ST ENGINEERING OF MOBILE AT BFM ON NR#: 58740 D AND DRILLED IAW 51-44-11, ASSEMBLED AND INSTALLED IAW SRM 51-4 2-11 AND RESTORED SURFACE PROTECTION OVER BOLTS AND NUTS IAW SRM