What was found
AFER EVALUATION OF AFT WET AREA FLOOR BEAM AT STA. 986.5, FOUND OUT OF LIMITS AND REQUIRE REPLACEMENT (REF: AAR NR 99977445) REMOVED & REPAIR OF AFT WET AREA FLOOR BEAM AT STA 986.5 IAW 737 -700 SRM 53-70-51-2R-4. THIS REPAIR IS A CATEGORY A. NO INSPECTI ON INTERVALS REQUIRED (WORK ACCOMPLISHED BY V939602 & AAR QC A-54 V918832)