What was found
FOUND CORROSION ON STR 22R AT STA 1006 R/H SIDE UNDER AFT WET AREA...REF BAM N/R# 1517657 FOR WORK ACCOMPLISHED PART 2 OF THE LATEST REVISION OF EC/RA 5330-07118 ON OR BEFORE 09-FEB-2025. INTERIM REPAIR ACCOMPLISHED AT FUSELAGE SKIN STA 1006 BETWEEN S-21R & S-24R - ACCOMPLISH INITIAL INSPECTION REQUIREMENTS PER TOMC APPROVED DIP CARRY. IAH MX PERFORMED INTERIM REPAIR PER TOMC-APPROVAL FROM SC1ELBYC COMMENT PART 1 REF ECRA 5330-07118. PLACED ON DIP TO ACCOMPLISH INITIAL INSPECTION REQUIREMENTS PER PART 2 OF THE LATEST REVISION OF EC/RA 5330-07118 ON OR BEFORE 09-FEB-2025.