What was found
GEAR DOOR INDICATION AFTER TAKEOFF. MSG CLEAR AFTER QRH PROCEDURE. LIFTED AC OFF GROUND USING JACKS REF MM 07-11-01-852-016. TILT ACTUATOR REF LP 5353105 FOUND BRAIDED HYD LINE ON TRUNK POSITION ACTURATOR SPLIT AND LEAKING FLUID. UPDATE, FOUND ON RIGHT MAIN GEAR REMOVED DAMAGED LINE AND INSTALLED SERVICEABLE ONE PER AMM 32-32-15-404-007., LEAK CHECK GOOD AT THIS TIME. PERFORMED MAIN LANDING GEAR EXTENSION AND RETRACTION SYSTEM TEST REF MM 32-32-00-705-003, TEST PASSED NO ISSUES FOUND AT THIS TIME. AC OK FOR SERVICE. PERFORMED HYD LEAK CHECK OF HYD PERFORMED REQUIRED RII INSP AND VERIFIED GEAR EXTENSION AND RETRACTION SYSTEM OPERATES AS REQUIRED WITH NO LEAKS. REF AMM 32-32-00-705-003. SERVICED LEFT HYD PER AMM 12-12-01-613-015.