What was found
REPAIR R/H HORZ STAB LWR SKIN CUTOUT TO ACCESS RIB DAMAGE AT STAB STA 120.3 REPAIR AND EXT.LFEC INSP.WITH REPEAT INSP EVERY 9,000 FLT CYCLES REPAIRED SKIN IAW SRM 55-10-01-2R-11. REQUIRES DIP IAW TABLE 204. INSP THRESHOLD 56,000 TOTAL FLT CYCLES DETAILED VISUAL ADD EMP:U241494,U347296,U245894 VERIFIED