What was found
REPAIR L/H HORZ STAB LWR SKIN CUTOUT TO ACCESS RIB DAMAGE AT STAB STA 138.70 AND EXT.LFEC INSP.WITH REPEAT INSP EVERY 9,000 FLT CYCLES REPAIRED SKIN IAW SRM 55-10-01-2R-11. REQUIRES DIP IAW TABLE 204. INSP THRESHOLD 56,000 TOTAL FLT CYCLES DETAILED VISUAL INSP ADD EMP:U397695,U245894,U236064 VERIFIED