What was found
DURING THERMOGRAPHY INSPECTION OF THE R/H ELEVATOR, NDT NOTED INDICATION OF A POTENTIAL REPAIR OF THE TOP PANEL LOCATED APPROXIMATELY 99" FROM THE I/B EDGE AND 137.75" FROM THE AFT EDGE. AREA OF CONCERN IS LABELED AS INDICATION "11". W/C:697 54 REPAIRED DAMAGED AREA ON R/H ELEVATOR UPPER SKIN, 99"FROM I/B ED ENGBFM GE AND 13.75" FROM AFT EDGE IAW A320 SRM 55-21-11-300-007, PAR 2 .A.(16), AND INCORPORATED REPAIR ON NR#69753 ON THIS NR IAW A320 SRM 55-21-11-283-002 PAR 1.A. W/C:69754 EMP:V933814 STA:ST