As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING THERMOGRAPHY INSPECTION OF THE R/H ELEVATOR, NDT NOTED INDICATION OF A POTENTIAL REPAIR OF THE TOP PANEL LOCATED APPROXIMATELY 63.5" FROM THE I/B EDGE AND 10.75" FROM THE AFT ED GE. AREA OF CONCERN IS LABELED AS INDICATION "7". W/C:69750 REPAIRED R/H ELEVATOR, REPAIR NO.7 IAW A32 SRM 55-21-11-300-007 AND SRM 51-77-11-911-023 TO BE PAINTED ON NR#69754. W/C:69750 EMP:V933814 STA:STENGBFM