As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURINGTHERMOGRAPIC INSPECTION OF THE L/H RUDDER SIDE PANEL, NDT NOTES WATER INGRESS AT THE 11TH FASTENER FROM THE TOP AT 6.25" F ROM THE TRAILING EDGE. INDICATION MEASURES AT 4.75 X 3.25" () LH RUDDER SIDE PNL REPAIRS COMPLETED AS REQUIRED- SMR 55-41-13-3 00-025-COMPOSITE REPAIRS- SRM 51-77-11-911-018 FORM''S 44-0008 ATTACHED. EMP#:V933812 WORK ACCOMPLISED AT ST ENGINEERING OF MOBILE AT BFM ON NR# 69936.