As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING THERMOGRAPHIC INSPECTION OF THE L/H RUDDER SIDE PANEL, NDT NOTES WATER INGRESS AT THE 12TH FASTENER FROM TOP AT 6.75" FROM THE TRAILING EDGE. INDICATION MEASURES AT 3.5" X 3.0". () LH RUDDER SIDE PNL REPAIRS COMPLETED AS REQUIRED SRM 55-41-13-30 0-025 COMPOSITE REPAIRS- SRM 51-77-11-911-018 FORM''S 44-008 ATTACHED EMP#: V933812 WORK ACCOMPLISHED AT ST ENGINEERING OF MOBILE AT BFM ON NR#: 69937