What was found
LIGHTNING STRIKE LIGHTNING STRIKE INSPECTION REQUIREMENTS DMC-B787-A-05-51-19-00A-311A-A CREATING DIP TO RECHECK DAMAGE TOMC APPROVED TOMC-APPROVAL FROM SC1ELBYC COMMENT INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE. REF LOGPAGES 5727363 AND 5727382 CREATED FOR PHASE 2 INSPECTION. PHASE 1A AND 1B LIGHTNING STRIKE VISUAL INSPECTION CARRIED OUT AS PER DMC-B787-A-05-51-19-00A-311A-A. PHASE 1A AND 1B LIGHTNING STRIKE INSP ACCOMPLISHED. PHASE II INSPECTION MUST BE COMPLETED WITHIN 15 FLIGHT CYCLES FOR THE HORIZONTAL STABILIZER AND ELEVATOR. TOMC APPROVED : QC REVIEWED. RECORDS UPDATE OK TO CARRY THE PHASE 2 INSPECTION FOR THE HORIZONTAL STABILIZER AND ELEVATOR WITHIN 15 FLT CYCLES PER AMM 05-51-19. CARRIED DIRECTLY BY TOMC TOMC-APPROVAL FROM SC1ELBYC COMMENT TOMC APPROVED : QC REVIEWED. INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & T/A: 15 FC....AZ/U370830 UPDATE. TOMCQC REV PERFORMED PHASE II INSPECTION OF HORIZONTAL STABILIZER AND ELEVATOR PER AMM DMC-B787-A-05-51-19-00A-311A-A NO SIGN OF LIGHTNING STRIKE EVIDENT AT THIS TIME. PHASE 1A AND 1 B LIGHTNING STRIKE INSP ACCOMPLISHED. PHASE II INSPECTION MUST BE COMPLETED WITHIN 50 FLIGHT CYCLES FOR THE FUSELAGE, VERTICAL STABILIZER, AND RUDDER. TOMC APPROVED : QC REVIEWED. RECORDS UPDATE OK TO CARRY THE PHASE 2 INSPECTION FOR THE FUSELAGE, VERTICAL STABILIZER, AND RUDDER WITHIN 50 FLT CYCLES PER AMM 05-51-19. CARRIED DIRECTLY BY TOMC TOMC-APPROVAL FROM SC1ELBYC COMMENT TOMC APPROVED