What was found
LE SLAT ASYM CAUTION UPON FLAP RETRACTION BETWEEN 1 AND UP FLAP NEEDLES BOUNCED DURING PILOT DEBRIEF THE CAPTAIN INDICATED THAT THE FLAPS/SLATS NEVER DID GET TO 0 POSITION DETENT. FSEU BITE SHOWED 1 FAULT. LE OUTBD ASYM WITH MESSAGE 27-80121 MESSAGE WAS ACTUALLY 27-81021. ACP RESISTANCE AND INDUCTANCE MEASUREMENTS ON RT HAND OB LE SLATS REF AMM 27-88-99-206-001. NO SIGNIFICANT FINDINGS. ACP VISUAL CHECK OF UNIT, ASSY, PRO OFF 76-3260-9-0005 0977 ON 76-3260-9-0005 9028 UNIT, ASSY, SENSORS & CHECKED GAP MEASUREMENTS REF AMM 27-88-01. NO FINDINGS. ACCOMPLISHED LE AND TE FLAP OP'S CHECK PER AMM 27-81-00/27-51-00. FLAP OPERATION AND INDICATION WAS NORMAL WITH NO EICAS MSG'S OR WARNING LIGHT.