What was found
CREW REPORTED PROBLEM MOVING STAB TRIM AND COMPLETED AN AIR RETURN, UPON ARRIVAL FOUND THAT STAB TRIM CONTROL (B10) ON THE P6-2 PANEL HAD BEEN PULLED AND COLLARED. MEL FOR AUTO SPEED BRAKE WAS ACCOMPLISHED LAST NIGHT, CB FOR AUTO SPEED BRAKE ON P6-2 (B9) WAS NOT PULLED AND COLLARED REF MEL LP 5974951. AUTO SPEED BRK AND SPEED BRK LOAD ALEVIATION MEL''S ON LP5975056 AND LP5974951 HAVE BEEN UP UPDATED WITH CORRECT C-B CONFIGURATION AND ADDED IPAD PICTURES. ACP''D VISUAL INSP OF JACKSCREW AREA, NO DISCREPANCIES FOUND. ACP''D BOTH MANUAL AND ELECTRIC HORIZONTAL STAB TRIM TESTS, STAB TRIM PASSED TESTS, FULL TRAVELS SMOOTH ANOMALIES. AMM 27-41-00-700-801, 27-41-00-700-803. SHOULD READ : FULL TRAVELS SMOOTH NO ANOMALIES.