Service difficulty report · Connector · Airbus A319131

Difficulty date
October 16, 2023
Submitted
October 18, 2023
Operation
Air carrier
Aircraft
N836UA
Make and model
Airbus A319131
Aircraft serial
1460
Aircraft time
68,463 hours, 30,262 cycles
Part
Connector
Part number
UNKNOWN
Part serial
NA
Condition
Loose
Location
P2/T2 Sensor, E1
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

EPR MODE FAULT - ENG 1. REFER TO TSM CHAPTER 77 ECAM AND UAL A32 0 MEL CARD 73 120. P2 T2 SENSOR FAULT ON POST FLIGHT REPORT INSPECTED AND FOUND CONNECTOR "B" LOOSE ON ENGINE 1 P2/T2 SENSOR. RESECURED AND NO FAULT MSG ACTIVE AT THIS TIME. REQUIRES OPS CHECK. ADD EMP:U393973 PERFORMED TSM 73-22-00-810-817-B. FAULT NOT REPRODUCED WITH ENGINE RUN REF AMM 71-00-00-710-047. ADD EMP:U019265,U399434,

More about the Airbus A319-131