As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STRING SPLICE AT FR66, STR26R, HAS CORROSION A3NB-53-3-6185 PER HAECO LCQ NON ROUTINE 9296784/40784. FOUND STRINGER SPLICE TO BE OUT OF LIMITS IAW SRM 51-71-11 MAX L AND SRM 51-72-11-911-001 AT FR66 STR26R. RESTORED SURFACE PROTEC OSS .086" REMAINING .010" MAX ALLOWABLE LOSS .004" LENGTH 2" WID TION IAW SRM 51-23-11 AND SRM 51-23-12/001 INSTALLED FABRICATED STRINGER SPLICE NR 40856 SO 37520 LOG # 9296856 IAW SRM 51-42-11-11 SRM 53-41-13-50-A