What was found
FRAME 35 STR 30 RH HOLE #2 HAS CRACK INDICATION IN FRAME LAYER 7 O''CLOCK POSITION 30% SCREEN HEIGHT. REPAIRED HOLE #2 AT RH FR35 STR30 IAW ECRA 5331-03064. CREATED CORRECT TO READ: PERFORMED INTERIM REPAIR RH FR35 STR30 HOLE #2 DIP FOR PERMANENT REPAIR TO BE ACCOMPLISHED ON OR BEFORE 2 MAY AT IAW ECRA 5331-03064 2024. ALL WORK PERFORMED IAW ECRA5331-03064. SEE LOG PAGE 6262209 AND LOG PAGE 626270 FOR DIP REQUIREMENTS PER PAGE 2 OF 10, PART 1: INTERIM REPAIR STEPS 2 AND 3 OF ECRA5331-03064.