Service difficulty report · Power Supply · Boeing 737724

Difficulty date
February 26, 2024
Submitted
February 28, 2024
Operation
Air carrier
Aircraft
N27724
Make and model
Boeing 737724
Aircraft serial
28791
Aircraft time
76,986 hours, 27,869 cycles
Part
Power Supply
Part number
D71702030
Condition
No Test
Location
Emergency Lights
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(SUPPORT TASK) EMERGENCY POWER SUPPLY (M1674) FAILED CHARGE AFTER TWO DAYS OF INSTALLATION (FOR SERVICE DIFFICULTY REPORT (SDR) FOR SDR, REFER TO CARD 4135/37160 ATTACHED FOR WORK PERFORMED. REMOVED AND REPLACED EMERGENCY POWER SUPPLY (M1674) IAW AMM 33-51-06-960-806. SYSTEM CHECKS GOOD. REMOVED P/N: D717-02-030 S/N: 6580 INSTALLED P/N: D717-02-030 S/N: 189512.