What was found
L ENG EEC MODE EICAS ILLUMINATED AFTER ENG START ENG1 EPR INDICATION INOP IN BOTH EICAS AND STBY TRIED CYCLING OF ACCOMPLISHED TROUBLESHOOTING PER FIM 73-21 FAULKT TREE 826, EEC MODE SELECTOR SWITCH, NO HELP. ALSO TRIED ENG 1 RESTART AND FOUND P2/T2 PROBE (T867) AT FAULT PART NIS AT GIG.PN 0154ED2 AFTER ROLL BACK FOR START EEC GOES INTO ALT MODE AND EPR M&P E 76-7323-9-9003. INDICATION REMAINS INOP ADD EMP:U399390 DISCREPANCY OR MSG WERE FOUND. PERFORMED T/S IAW FIM 30-34-803 SHEET 2 BLOCK 2. FOUND CONECTOR D11434 PIN 3 OUT OF POSITION. REF WDM 30-34-11-1.1 . IT WAS REINSERTED PIN 3 IN CORRECT POSITION. ( REF SWPM 20-60 AND 20-63). PERFORMED SYSTEM TEST IAW AMM 30-34-00-715-016, START LH ENG TWICE AND RUN-UP FOR 15 MINUTES IAW AMM 71-00-00. EPR ENG INICATION OK AT EICAS & SEI, NO DISCREPANCIES AND NO MESSAGES NOTED. AIRCRAFT GOOD SERVICE.