What was found
TOP OF VERTICAL STAB DAMAGED. PERORMED STEPS 1 AND 2 OF AVO12217, REFERENCE AMM 55-33-21-000-801 FOR STEP 2. C/W HFEC REF NDT PART 6-51-00-00 PREC 16 AND PROC 23 IAW AVO 12217 STEPS 3 AND 4, NO CRACKS DETECTED. COMPLIED WITH STEP 5 OF AVO12217 IAW AMM 55-33-21-400-801. PERFORMED OPS CHECK OF THE RUDDER (STEP 6 OF AVO12217) IAW AMM 27-21-00-700-817-002. NO DEFECTS DISCOVERED AFTER ACCOMPLISHING STEP 1 AND 2 OF AVO1227 ON RUDDER OR STRUCTURE UNDERNEATH THE CAP ASSEMBLY. ACPD STEP 7 OF AVO 12217, OPER CK OF LOCALIZER ANTENNA GOOD IAW AMM 34-51-02/401, THIS COMPLETES AVO INSPECTION. ALL WORK ACCOMPLISHED IN C/W EC/RA # 5530-02002.