What was found
DURING CLIMB FUEL IMBAL IN MAIN WITH 5000LBS REMAINING IN CENTER TNK. ON ARRIVAL FOUND RIGHT MAIN TANK READING 800 LBS HIGH COMPARED STICK TABLE REF. AMM 12-11-02-993-953. FUELED MAIN TANKS TO 8500 INDICATION. (BLANK). REQUEST DEFERRAL PER MEL. DDP C/W DEFERRED PER MEL, DDP C/W. FUEL QTY VERIFIED TO 8500 LBS. IN TO STICK READING. ALL OTHER TANKS ARE READING WITHIN LIMITS PER LBS USING STICK 8 AT 3.2 UNITS, RIGHT TANK IS NOW SHOWING NO RIGHT MAIN TANK. ACP''D OF RH MAIN TANK BUSSING PLUG GROUND BONDING CHECK CDCCL. INSP ACP''D, REF GMM 09-10-05. BOND CHECKS WITHIN TOL. *DM* REF. FIM 28-41 TASK 813 & 814 FOR TROUBLESHOOTING. MICROBIAL GROWTH TEST KIT AVAILABLE. FOLLOWED FIM28-41- TASK 803 COMPLIED WITH FAULT ISOLATION ADDED TEST KIT(S) PART NUMBERS (NIS IN SAT) PROCEDURE 803.G.(1) UNABLE TO COMPLY WITH 803.G.(2) DUE TO NO MICROBIAL GROWTH TEST KIT AVAILABLE.