Service difficulty report · Outflow Valve · Boeing 737724

Difficulty date
April 8, 2024
Submitted
April 10, 2024
Operation
Air carrier
Aircraft
N29717
Make and model
Boeing 737724
Aircraft serial
28936
Aircraft time
73,610 hours, 26,339 cycles
Part
Outflow Valve
Part number
40631997201AB
Part serial
9819763
Condition
Failed
Location
Cabin Pressure
Part time
60,815 hours, 26,386 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PRESSURIZATION AUTO FAIL LIGHT ILLUMINATED UNABLE TO CONTROLL PERFORMED PRESSURIZATION SYSTEM GROUND TEST PER AMM TASK 21-31-00. BITE TEST SHOWED OUTFLOW VALV FAIL CODE. REMOVED AND REPLACED AFT OUTFLOW VALVE PER AMM 21-31-03. OP CHECK GOOD.