What was found
FLOOR SUPPORT ANGLE IS CORRODED UNDERNEATH AROUND MULTIPLE NUTPLATES, LOCATED BETWEEN LFS 1263 TO LFS 1285, LBL 7 (STREAMER # 70191). NEW ALC FLOOR SUPPORT FABRICATED ON AMES DOCUMENT 47609FAB15, #5360-01785. ESFR 1035933 LOCATED BETWEEN LFS 1263 & 1285, LBL7 WAS MATCH DRILLED IAW AMES DOCUMENT 47609FAB15, STEPS 5 AND IS TO BE INSTALLED ON W/O 16879 ACCOMPLISHED BY & 8-0100-0244, ENTRY NO 1. NO FURTHER ACTION REQUIRED UAL EC/RA