What was found
RAMP REPORTED DAMAGE LT SIDE FWD OF TOLIET SERVICE PANEL. JUST AFT OF BS 807 BETWEEN S25L & 26L. HOLE/ CRACK MEASSURES 2 1/2 " DENT IS APPROX 4" X 1 1/4 WIDE LOCKING FOR MX FERRY COMPLIED WITH EC/RA: 5330-07246 REMOVED FASTENERS FROM STRINGERS AND FRAME IN DAMAGED AREA IAW SRM 51-42-00. CUT OUT DAMAGED SKIN REF AVO 12561 , STEP 3 . PERFORMED HFEC ON EDGE CUT OUT ON SKIN PER NDT MANUAL READY FOR HFEC OF EXISTING FASTENER HOLES PER AVO12561 STEPS 6 ACP,D HFEC ROTO INSP. REF NTM 51-00-00-16 P6 OF AVO 12561 STEP ALSO ACP,D HFEC ROTO INSP. REF NTM 51-00-00-16 P6 OF AVO 12561. NO CRACKS DETECTED. & 7. NDT MANUAL PART 6, 6. NO CRACKS FOUND STEP 7. NO CRACKS FOUND 51-00-00, PROCEDURE 16. ACPD HFEC ROTO PROBE OF 6 EACH HOLES OPENED FOR BETTER ACCESS PER B737 PART 6, 51-00-00 PROC 16 FOR BOTH COUNTERSINK AND STRAIGHT HOLE INSP. NO CRKS DETECTED MANUFACTURED STRUCTURAL FILLER REF AVO 15561, SRM 51-30-01 STARTED TO PICK UP HOLES IN DOUBLER REF. AVO12561 STEP 10B SECTION 46 L/H FUSELARGE DAMAGE AREA (COUNTER SUNK NEW DOUBLER REPAIR) STA 807 ,S25L AND S26L AFFECTED STRUCTURAL AREA. REF, SRM 56-60-01-01. FROM LP 7935466, STARTED DRILLING FROM LP 7935466.