As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR BEAM WEB P/N 141A5181-6 AT BS 185 AND APROX LBL 24.7 REQUIRES ENLARGEMENT. SEE NON-ROUTINE # 001987923 FOR WORK STEPS ACCOMPLISHED. RECEIVED EC/RA 5310-08330, WHICH PROVIDES CAT A PERMANENT REPAIR INSTRUCTIONS. REPAIRED FLOOR BEAM WEB ACCESS HOLE I.A.W. EC/RA 5310-08330. REFERENCE NON ROUTINE # 001987923 FOR WORK STEPS ACCOMPLISHED.