What was found
EMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - DOOR 2R LOWER EMERGENCY EXIT SIGN CRACKED AND HALF BULBS INOP IDT C/W PROPER INSTALL AND OPS OF DOOR 2R LOWER EMERGENCY LIGHT REF GMM 09-10-05 UPON REMOVAL OF LENSE, FOUND COFFEE AND COFFEE GROUNDS REMOVED AND REPLACED DOOR 2R LOWER EMERGENCY EXIT SIGN ASSEMBLY WITH REFERENCE TO AMM 33-51-01. OPS CK GOOD.PARTS USED: 29-3351-3-0011,QTY :1 VERIFIED AREA IS CLEAN, ALL TOOLING REMOVED.