What was found
FLOOR BEAM FR 64-68 Y512 CORRODED AT HARDPOINT AT FR66 () REMOVE CORROSION I.A.W SRM 51-74-00 L=1.28" D=0.031" FOUND TO BE 104027 OUT LIMIT I.A.W SRM 53-41-14-283. REMOVED AND REPLACED FLOOR BE AM I.A.W SRM 51-42-11 (T93872) SEE ATTACH FORM 44-0008.