As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SIGNS OF A SMALL CRACK ON PRESSURE DECK AT STATION 663.75 AT APPX RBL 35. THIS LOG PAGE IS FOR ESFR REPORTING PURPOSES ONLY. SEE NON-ROUTINE 1980186 FOR WORK PERFORMED. 57-10-10-2R-3. REPAIRED VERTICAL PRESSURE DECK PER SRM 57-10-10-2R-3 CUT OUT DAMAGE AND INSTALL FILLER AND DOUBLER PER NOTED SRM INSPECTION NOT REQUIRED