Service difficulty report · Controller · Boeing 737724

Difficulty date
June 21, 2024
Submitted
June 21, 2024
Operation
Air carrier
Aircraft
N38727
Make and model
Boeing 737724
Aircraft serial
28797FAL
Aircraft time
77,389 hours, 27,366 cycles
Part
Controller
Part number
5483766
Part serial
049C10532
Condition
Inoperative
Location
Cabin Temp
Part time
67,749 hours, 23,665 cycles
Stage of operation
NR
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT IS HOT. CANNOT BE COOLED ON GND OR AIR UNTIL REACHING CRUISE. BITE TEST CABIN TEMP CONTROL, CTC HAS NO POWER TO BIT TEST, REST SYS, NO HELP. R & R CABIN TEMP CONTROLLER PER AMM 21-61-01 OPS CHKD GOOD. PERFORMED TEST, BOTH PACKS & SELECTING CABIN TEMP, FOUND RT AIR MIX VALVE GOING TO FULL HOT IN AUTO MODE WHEN COLD SELECTED. PERFORMED FIM TASK 21-52 TASK 856, FOUND 35 DEGREE SENSOR, CONTROL VALVE & MODULE GOOD, BUT AIR MIX VALVE FAILED. REMOVED RT AIR MIX VALVE PER AMM 21-61-02-000-801. REPLACED TEMP CONTROL REF AMM. 21-61-02. DID NOT FIX. AUTO MODE STILL NOT COOLING RT PACK. MANUAL MODE CHKD GOOD. CABIN WAS ABLE TO BE COOLED IN MANUAL MODES. R & R CABIN TEMP CONTROLLER IAW AMM 21-61-01, OPS CHKD GOOD.