What was found
FOUND DENT AND GOUGE ON LT AFT FUSELAGE JUST BEHIND PRESSURIZED AREA. APPROX STA 1040 STGR 11-12. PERFORMED REMOVAL OF DAMAGE PER SRM 53-80-01 REPAIR 7 REMOVAL OF DAMAGE. COMPLIED WITH STEP 4F HFEC INSPECTION REF NDT PART 6-51-00-00-23 OF CUTOUT EDGE, NO CRACKS FOUND. REMOVED ALL EXISTING FASTENERS IN REPAIR AREA, PER SRM 53-80-01-2R-7 STEP 4(C). STEP 4(G). ACCOMPLISHED INSURANCE CUT. ACCOMPLISHED STEP 4H, HFEC HOLE PROBE INSPECTION REF NDT PART 6-51-00-00-16 NO CRACKS OR DEFECTS FOUND. ACCOMPLISHED HFEC COUNTERSINK INSPECTION STEP 4I, REF NDT PART 6-53-30-00-4, NO CRACKS OR DEFECTS FOUND. INSTALLED ALL REPAIR PARTS AND FASTNERS, FILLET SEAL DOUBLER/TRIPLER PER SRM 53-80-01-2R-7 REPAIR 7, STEP 4.(T-W).