What was found
CRACK INDICATION NOTED AT RH FR20 DOOR STOP FITTING #1, HOLE #3 WHILE ACCOMP''G INSP IAW EA5311-02164 (B), AT BFM HMV ON N/R 93794. 1.6 AS FOLLOWS: RH FR20 DOOR STOP FITTING #1, HOLE #3 WAS REP''D ER PART 2 OF LATEST REVISION OF ECRA5311-03231 ON/BEFORE ACFT RE RVALS NOT TO EXCEED 14,500 FC THEREAFTER (FH NOT RELEVANT). AT BFM, RPR IS PERMANENT SOLUTION W/ INSP REQM''TS. ACCOMP.INSP P ACHES 41,641TTL FC, (FH NOT RELEVANT) ACCOMP REPEAT INSP AT INTE ACCOMPLISHED INTERIM REPAIR IAW ECRA5311-03231 AND AIRBUS REPAIR DRAWING R531-13118(F) AS NOTED PER PART 1.