What was found
BIRD STRIKE. INSPECTION REQUIRED PER AMM. HIT UNDER CAPT NOSE UNDRSCREEN AT 210KTS 7K FT. FWD DENT EDGE IS X = 13" AND Y = 10" FROM THE CENTER AREA OF THE STATIC PROBE PORT CLOSE UP DENTS ARE ABOUT 6 IN LONG 3IN WIDE 1/4 DEEP AND 5 IN APART DENT 1 FWD DENT X = 6 Y = 4 A = < 2.75 / 1.25 > D = 6/32ND" DENT 2 AFT DENT X = 6.25 Y = 4 A = < 2.25 / 1.75 > D = 5/32ND" OK TO CARRY DMG ON L/H SIDE FOR 5 FC. DENT MUST BE REEVALUATED BY QC. C/W BIRD STRIKE INSPECTION PER AMM 05-51-14-200-803-A FOUND 2 DENTS ON L/H SIDE C/W INSPECTION PER SRM 53-11-11-283-012 OK TO CARRY DMG ON L/H SIDE FOR 5 FC. DENT MUST BE REEVALUATED BY QC MEASURED DENTS IAW SRM 53-11-11-283-012. DE