What was found
RH ELEVATOR UPPER SURFACE HAS EVIDENCE OF WATER INGRESS 29 INCHES FROM IB EDGE, 18.5 INCHES FROM AFT EDGE, 1.75 INCH DIA., DRILLED WITNESS HOLES ON R/H ELEVATOR UPPER SURFACE 29IN FROM I/ 75, B 18.5 FROM T/E ZONE A 1.5IN DIA. FOUND NO LIQUID IAW A319 AMM 55-20-00-200-006-A01 PAR 4 A (7) REPAIRED AREA IAW A319 SRM 55-21 -11-300-004 CATEGORY A REPAIR.