As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ALL LAVS ARE INOP. NO FLUSH. WE ARE AT FL320 REPLACED VACUUM BLOWER IN ACCORDANCE WITH AMM REFERENCE 38-32-05/401. PERFORMED OPERATIONAL CHECK OF TOILET FLUSH. ALL TOILETS FLUSH AND OPERATES NORMAL AT THIS TIME.PARTS USED: 99-3832-9-0006,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1503999 SN OFF 5763 BLOWER, VACUUM, OFF 99-3832-9-0006 5763 ON 99-3832-9-0006 8430