What was found
WHILE PERFORMING A CAT III LAND VERIFICATION CHECK. STAB TRIM STOP AT 7 UNITS. TRIED TO MANUALLY TRIM IT BUT HAD NO SUCCESS. PERFORMED A VISUAL CHECK OF THE AFT CABLE DRUM AND FOUND THE CABLE TO BE OUT OF PLACE AND SKIPPING GROVES IN THE DRUM. FOUND BIRD CAGED STAB CABLE JUST AFT OF E&E COMPATMENT, FWD PIT FWD CEILING. FOUND ADDITIONAL CABLE BIRD CAGED CABLE AFT OF AIR CONDITIONING DISTRIBUTION BAY. REMOVED BOTH STA AND STB CABLES AND ROUTED NEW CABLES PER MM 27-41-82-400-801 UP TO AND INCLUDING STEP H3. VERIFIED INSTALLATION OF ROTOR CONTROL, CABLES, UP TO STEP STEP I. REF AMM TASK 27-41-82-400-801. (RII) REF GMM 09-25-05. COMPLIED WITH STEPS H4 & H5. PERFORMED MM 27-41-82-400-801 STEPS I TO I.8. VERIFIED INSTALLATION OF ROTOR CONTROL, CABLES, UP TO I.8 TO END. OPS CHECKS GOOD REF, TASK 27-41-82-400-801. (RII) REF GMM 09-25-05. PERFORMED MM 27-41-82-400-801 STEPS I.8 TO END. OPS CHECKS GOOD. NO OTHER DAMGAED NOTED. CAT STATUS FULL CAPABLE. OK TO CONTINUE