What was found
MOMENTARY /ONE SECOND/ ACTIVATION OF CAPTS STIC K SHAKER AFTER L IFTOFF. APPROX 75-100 AGL ON INVESTIGATION FOUND DRIVER CARD 10 FAULTING ON PSEU. FAULT ERASED, PSEU TEST CARRIED OUT IAW AMM 33-09-04-704-013, NOW NO FAULTS EXIST. L AND R STALL WARNING TEST CARRIED OUT IAW AMM 27-32-00-715-004-003, ALL TESTS NORMAL. DURING INSTALLATION OF PSEU REF AMM TASK 32-09-04. NEW PSEU FAIL ON FIT. STRONG ODOUR SMELL. SDR INITIATED REF GMM 04-20-16. ADD EMP:U405158