What was found
STRINGER 27L BETWEEN STA 320 AND STA 375 CORRODED, PUNCTURED, AND CRACKED. INTERIM REPAIR TO THE FUSELAGE STRINGER 27L CORROSION, PUNCTURE AND CRACK DAMAGE BETWEEN STA 350 - STA 420 WAS ACCOMPLISHED PER ECRA 5330-07352 PART 1 AT GYR. ACCOMPLISH PERMANENT REPAIR ON OR BEFORE MAR 26, 2026. CREATING DIP PER ECRA 5330-07352 PART 1 ITEM 2. WORK ACCOMPLISHED ON AERSALE NR 004391 31428. TOMC APPROVED DIP CARRY. AERSALE GYR MX PERFORMED THE INTERIM TOMC-APPROVAL FROM SC1ELBYC COMMENT REPAIR TO THE FUSELAGE STRINGER 27L CORROSION, PUNCTURE AND CRACK DAMAGE BETWEEN STA 350 - STA 420 PER PART 1. PLACED ON DIP TO ACCOMPLISH PERMANENT REPAIR ON OR BEFORE MAR 26, 2026 REF ECRA 5330-07352, REV A. QC RECORDS UPDATE QC REVIEWED T/A: ON OR BEFORE 26MAR26