UNABLE TO CONTROL COCKPIT TEMP. UPON ARRIVAL CHECKED BOTH ZONE TEMP CONTROLLERS NO FAULTS PERFORMED TEST ON BOTH CONTROLLERS NO FAULTS UPDATED LABOR HOURS AND GROUND TIME REMOVED AND REPLACED #2 PACK ZONE TEMP CONTROLER PER AMM 21-61-20. BITE TEST PASSED.PARTS USED: 58-2161-9-0002,QTY :1 1334849,QTY :1 ADD EMP:U342887 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1334849 SN OFF 1437 CONTROLLER, CAB OFF 60-2161-9-0001 1437 ON 60-2161-9-0001 1566 UPON BITE TEST ON #1 CONTROLLER, FOUND TCV FAULT LIGHT ON . SUSPECT TEMP CONTROL VALVE INOP. TCV PN 398908-6. PART ORDERED TO BALLPARK DROPOFF. REMOVED AND REPLACED #1 TCV OPS AND LEAK CHECK GOOD BITE BOTH #1 AND #2 CONTROLLERS NO FAULTS FOUND PER 21-51-10PARTS USED: 58-2151-9-0011,QTY :1 58-2151-9-0009,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1359782 SN OFF 5756 VALVE, CONTROL, OFF 58-2151-9-0009 5756 ON 58-2151-9-0011 6229 AIRCRAFT OK TO CONTINUE