What was found
INTERIM REPAIR TO RH SIDE NUMBER 3 WINDOW FRAME E-F POST CRACK INDICATIONS PRESENT ON THE FIFTH FASTENER HOLES FROM THE BOTTOM AFTER SECOND HFEC. REF EC/RA# 5311-03294 ACCOMPLISHED A PERMANENT REPAIR OF THE RH #3 WINDOW FRAME E-F POST PER PART 3 OF EC/RA 5311-03294 ON OR BEFORE 18 OCTOBER 2026 VERIFIED SFR #1037462 ENTERED. VERIFIED,STEP 13 COMPLIED WITH. AS PER ECRA 5311-03294. ALL WORK PERFORMED ON NON ROUTINE # 002235573 IN AIW EC/RA# SFR #1037462 ENTERED. INITIATED DIP IAW STEP 13 OF ECRA 5311-03294 5311-03294 ACCOMPLISHED A PERMANENT REPAIR OF THE RH #3 WINDOW FRAME E-F TOMC-APPROVAL FROM SC1ELBYC COMMENT POST PER PART 3 OF EC/RA 5311-03294 ON OR BEFORE 18 OCTOBER 2026 QC REVIEWED QC REVIEWED INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS REVIEW.