As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY EXIT LIGHTS ON BOTH AFT DOORS COMES ON AND OFF DURING LNG FOLLOWED TSM TASK 33-51-00-810-819-A (EMERGENCY EXIT LIGHTING FLICKER FAULT). CARRIED OUT OPERATIONAL CHECK OF THE EMERGENCY POWER UNITS BY BITE CHECK PER AMM TASK 33-51-00-710-001-A. RESULTS SATISFACTORY; NO FAULT MESSAGES OBTAINED, SYS OK LIGHT OBTAINED ON PTP 110RH PANEL.