What was found
LIGHTNING STRIKE AT STA. 690 STR. 36REMOVED RIVET REF SRM 51-40-02 BLENDED OUT THE DAMAGE REF SRM 53-00-01-R-8. REMOVED FASTENERS FOR DOUBLER REPAIR AND REMOVED THE DAMAGED SKIN REF SRM 53-00-01-2R-4 REQUEST NDT OPEN HOLE INSPECTION FOR FASTENERS REMOVED REF. NDT PART 6, 51-00-02 REQUEST NDT INSPECTION FOR DAMAGE CUTOUT AREA REF. NDT PART 6, 51-00-02 ACPD HFEC PER 777 NTM PART 6 51-00-02 ROTO PROBE AND PENCIL PROBE ALL FASNER OPEN HOLES AND DAMAGE CUT-OUT - NO CRKS FOUND MANUFACTURED FILLER 2024-T3 0.090" P.O.# 5352837. REF. SRM 51-00-01-2R-4 REMOVED MORE FASTENERS FOR DOUBLER REPAIR REF SRM 53-00-01-2R-4. REQUEST NDT OPEN HOLE INSPECTION FOR FASTENERS REMOVED REF. NDT PART 6, 51-00-02 MANUFACTURED DOUBLER 2024-T3 0.100" P.O.# 411048330. REF. SRM 51-00-01-2R-4 ACPD HFEC ROTO PROBE ON EXTRA OPEN HOLES- NO CRKS FOUND MANUFACTURED DOUBLER 2024-T3 0.125" P.O.# 3875056330 . REF. SRM 51-00-01-2R-4 CORRECTION ON FILLER 2024-T3 0.090" P.O.#9909645 M&E# 40-0604-3-1566 STARTED TO PICK UP HOLES ON THE DOUBLER AND FILLER REF. SRM 51-00-01-2R-4 ADD EMP:U423354 COMPLETED PICKING UP HOLES ON THE DOUBLER AND FILLER AND STARTED UPSIZING FILED FASTNERS TO THE FINAL SIZE REF. SRM 51-00-01-2R-4. BEGAN TO COUNTERSINK HOLES AND CUT THE REPAIR READY FOR CHAMFER AND STRINGER HOLES NEED TO BE BROUGHT UP TO FINAL SIZE REF SRM 53-00-01-2R-4 ADD EMP:121383 FINAL TRIM THE REPAIR, COUNTERSINK AND INSTALED REPAIR WASHERS, APPLIED ALODINE AND PRIMER UPDATED ESFR INFO