As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
R1 OUTER PANE SHATTERED ADDING PICS REMOVED F/O R1 WINDSHIELD REF AMM 56-11-11. ADD EMP:U409279,U381100 COMPLETED INSTALLATION OF R1 WINDSHIELD REF AMM 56-11-11 UP TO AND INCLUDING STEP H (9) (CABIN PRESSURE LEAK TEST). PERFORMED LEAK TEST REF AMM 05-51-91. LEAK CHECK GOOD, AND IS WITHIN LIMITS. INSTALLED NYLON CORDON, PASSED BONDING TEST, APPLIED SEALANT, TIME TO START CURE 2:15 P.M. COMPLETED STEP I TO END OF R1 WINDOW INSTALLATION REF AMM 56-11-11.