What was found
DOOR 4L TOMC REQUEST TO REMOVE DOOR SLIDE BUSSEL AND INSPECT ALL MECHANISMS AND INSTALLATIONS FOR DEFECTS. REF FUP 3198159 GAINED ACCESS TO ARMING/DISARMING LEVER & ITS ASSOCITED LINKAGES FOR DETAILED INSP REF AMM 25-66-10. FOUND NO LOOSE HARDWARE, BENT/BINDING RODS OR ANY OTHER DEFECTS. GIRT BAR TRACK WAS CLEANED AND LUBRICATED AFTER FINDING DEBRIS WITHIN THRESHOLD AREA AND FLOOR FITTINGS REF ECRA 2560-02189 REV E. AFTER CLEANING, FOUND NO BINDING OR OUT OF POS THAT WOULD CAUSE ARMING/DISARMING PROBLEM. REINSTALLED DOOR 4L BUSSEL REF AMM 25-66-01-404-044. OPS CHECK GOOD.